Equipments 
SOLAR CELL TESTER
The tester is assigned for terrestrial solar cell incoming/outcoming inspection with the purpose of optimizing parameters and preventing manufacture defects of solar modules.

 

 
Due to use of xenon pulse lump installed in the tester solar cells are not heated in process of inspection.The tester is IBM PC controlled with the possibility of selecting inspection duty: from simple check in a particular I-V curve point up to full I-V curve recording and statistical processing of measurement results.
 
MAIN TECHNICAL PARAMETERS
Uniform illumination field, mm
150 ґ 150 (± 1%) / 200 ґ 200 (± 2%)
Light flux intensity, W/m²
1000 (± 1%)
Light flux intensity adjustment range, W/m²
600 ÷ 1200
Light spectrum
AM 1.5 (IEC 904-9)
Measured current range, A
0.3 ÷ 5.0 (± 1%) / 0.1 ÷ 0.3 (± 3%)
Measured voltage range, V
0.1 ÷ 2.5 (± 0.5%)
Light pulse width, ms
7
Measurement duration, s
8
Reference sample
Monocrystalline Solar Cell
Power consumed (220 V, 50 Hz), W
100
Dimensions, mm
550 ґ 320 ґ 1000
Weight, kg
34
 

Parameters displayed on PC monitor:

open circuit voltage;
short circuit current;
voltage at maximum power;
current at maximum power;
maximum output power;
efficiency;
current at a given load voltage;
output power at a given load voltage;
fill factor;
I/V curve;
solar cell temperature.
Optionally as per customer's order:
shunt resistance;
series resistance;
reverse saturation current;
ideality factor.
 
The software attached gives the possibility to set reference sample parameters and light flux intensity, present measurement results in list, table and graph form, print displayed data, carry out statistical processing of measurement results.

 

 