- Plasma JSC
Hydrogen Thyratrons
Hydrogen
Tacitrons
Psuedospark Switches
Spark Gaps
Triggered
Three-Electrode Spark Gaps
Sharpening Spark
Gaps
High-Power
Spark Gaps
“Button”
Surge Arresters
Switching
Spark Gaps

- Pulsed Power Components:
Sharpening
Spark Gaps
This
type of two-electrode high-pressure metal-ceramic spark gaps are
intended for portable defectoscopic and medical x-ray installations,
pulsed-lasers systems and so on.
We offer
five main models of the spark gaps for pulse current of 1 kA, with anode
voltage between 100 and 300 kV and pulse repetition rate up to 50 Hz,
breakdown time of less than 2 ns.
Sharpening spark gaps
Type
|
Voltage, kV
|
Pulse current, kA
|
Switched energy, J
|
Dimensions
d H, mm
|
Service time
pulses
|
RО-48
|
100-140
|
0.4
|
0.5
|
40х55
|
107
|
RО-43
|
140-290
|
1
|
2
|
50х70
|
107
|
RО-49
|
180-200 (250)
|
1
|
6
|
70х80
|
107
|
RO-71
|
270-330
|
1
|
8
|
85x100
|
2x106
|
RО-72
|
230-270
|
0.8
|
6
|
85х100
|
2х106
|
All the
ratings in this data sheet are absolute, non simultaneous ratings